MEAN WELL LPC-150-350 150W 350V alimentation à sortie unique
Description du produit
MODEL |
LPC-150-350 |
|
OUTPUT |
RATED CURRENT |
350mA |
|
CURRENT ACCURACY |
±5.0% |
|
CONSTANT CURRENT REGION Note.5 |
215~430V |
|
RATED POWER |
150.5W |
|
RIPPLE CURRENT |
±5.0% |
|
RIPPLE & NOISE (max.) |
2Vp-p |
|
VOLTAGE TOLERANCE |
±2.0% |
|
LINE REGULATION |
±1.0% |
|
SETUP, RISE TIME |
1000ms, 80ms / 230VAC at full load |
|
HOLD UP TIME (TYP) |
16ms/230VAC at full load |
INPUT |
VOLTAGE RANGE Note.2 |
180~305VAC 254~431VDC |
|
FREQUENCY RANGE |
47~63HZ |
|
EFFICIENCY (Typ.) |
90% |
|
AC CURRENT (Typ.) |
1.7A/230VAC 1.5A/277VAC |
|
INRUSH CURRENT (max.) |
COLD START 40A(twidth=750μs measured at 50% Ipeak) at 230VAC |
|
LEAKAGE CURRENT |
<0.25mA/277VAC |
PROTECTION |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
|
OVER VOLTAGE |
440~470V |
|
|
Protection type :Shut down and latch off o/p voltage re-power on to recovery |
|
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
ENVIRONMENT |
WORKING TEMP |
-25~+50℃ (Refer to “Derating Curve”) |
|
WORKING HUMIDITY |
10~95%RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40~+70℃ 10~95%RH |
|
TEMP. COEFFICIENT |
±0.03%(0~50℃) |
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
SAFETY&EMC |
SAFETY STANDARDS |
IP67 approved ; refer to EN60950-1 |
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
|
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
|
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A |
QTHERS |
MTBF |
479K hrs min. MIL-HDBK-217F (25℃) |
|
DIMENSION |
191*63*37.5mm (L*W*H) |
|
PACKING |
0.74Kg; 20pcs/15.8Kg/0.95CUFT |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Derating may be needed under low input voltage. Please check the static characteristics for more details. 3. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 4. Refer to warranty statement. 5. Constant current operation region is within 50%~100% rated output voltage.This is the suitable operation region for LED related applications,but please reconfirm special electrical requirements for some specific system design. 6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. |
Groupes de Produits : Mean Well Led Driver / Alimentation Led > LPV / LPC signifie pilote bien conduit